5KW Off-Grid solar power system house use solar systems
5KW solar power system |
item | wattage | Voltage/electric current | price |
Solar inverter | 5kw | 96v | $519 |
Solar controller |
| 96v/50a | $252 |
Solar panel | 200w*20 | 36v | $2698 |
battery |
| 12v/200ah*16 | $3260 |
Total for system:$6729 |
Product Information
How the solar system working :
This Solar system not only have solar power system function, but also have Utility complementary function. When main power off , the solar system can switch automatically to take use off solar power from battery to run load, When solar power not enough and power off , it can switch automatically to main power and connect with grid electricity take use of main power .at the same time charging battery. This is very suit for home use.
Specifications: |
Model XD- | TNY50112-10 |
|
Solar Energy Module | Type | Monocrystalline silicon A level |
Power | 100W |
|
Daily Power generation | 0.5KWH |
|
(Sunshine according to 5H) |
|
Size(mm) | 1160×660×35×1 |
|
PV Controller | Control mode | Direct charge/PWM/MPPT |
Charge current | 10A |
|
Rated charging voltage | 12VDC |
|
Compulsive charging voltage | 14.8V |
|
Balanced charging voltage | 14.4V |
|
Floating charging voltage | 13.8V |
|
Recovery charging voltage | 13.3 |
|
Battery overvoltage protection/recovery | 16.5V/15V |
|
Protection function | Reverse connection, short circuit, overcharge, anti charge protection |
Display | LED |
PV Inverter | Rated Capacity | 500W |
|
DC voltage | 12V |
|
Undervoltage protection | 10.5V |
|
Inverter structure | Low frequency structure |
Mains input | 75VAC-125VAC or 145VAC-275VAC |
Inverter output | 110VAC+/-2% or 220VAC+/-2% |
Mains input charging current | 10A |
Working way | Mains priority/solar power priority (optional) |
Conversion time | ≤4ms |
Overload capacity | Overload 110% 30 seconds the machine automatically shut down; overload shutdown 120% 2 seconds; mains mode overload do not shutdown |
Conversion efficiency | ≥80% |
Output waveform | Pure sine wave |
Work environment | Temperature0-40°C,Humidity10-90% |
Cooling mode | Forced air cooling |
Protection function | Mains over / under-voltage, direct current is too high / undervoltage, the inverter output short circuit |
Display | LCD |
Output waveform distortion | ≤±0.3% |
Input and output frequency | The same with power system |
Battery | Battery Type | Deep cycle maintenance-free lead-acid battery |
Battery capacity | 100AH/12V×1 |
|
Discharge time(full Load calculation) | 1.3H |
|
Machine specifications | Size(mm) | 465×245×465 |
|
Weight | 48KG |
|
Remarks | Specification for reference.Subject to change without prior notice |