参数
功率 输出◆ Pure sine wave output;
◇ Built-in PWM charge controller optional;
◆ AC charge current 0-30A adjustable; AVR output;
◇ Low frequency toroidal transformer increase efficiency;
◆ Dedicated DCP chip design; stable and high-speed operation;
◇ Added fault code query function, easy to monitor the operation in real time;
◆ Supports diesel or gasoline generator, adapt any tough electricity situation;
◇ RS232 or RS485 communication port optional.
Specification | |||||||
Model: LW-T | 10212/24 | 20212/24/48 | 30224/48 | 40224/48 | 50248 | 60248 | |
Rated Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | |
Battery Voltage | 12/24VDC | 12/24/48VDC | 24/48VDC | 48VDC | |||
Size(L*W*Hmm) | 550*243*175 | 570*261*199 | |||||
Packing Size(L*W*Hmm) | 605*305*270 | 625*320*295 | |||||
N.W.(kg) | 11 | 19 | 20.5 | 22.5 | 24 | 26 | |
G.W.(kg) (Carton Packing) | 12.5 | 20.5 | 22 | 24 | 26 | 28 | |
Parameter | |||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||
AC Input Voltage Range | 85VAC~138VAC /89VAC~144VAC / 93VAC~150VAC / 170VAC~275VAC / 178VAC~288VAC /186VAC~300VAC | ||||||
AC Input Frequency Range | 45Hz~65Hz | ||||||
Output | Efficiency | ≥85% | |||||
Output Voltage(Battery Mode) | 110VAC±2% / 115VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||
Output Frequency(Battery Mode) | 50/60Hz±1% | ||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||
AC Output Voltage Range | 110VAC±10% / 115VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | ||||||
AC Output Frequency Range | Tracking Automatically | ||||||
Inside Solar controller (Optional) | Charging Mode | PWM | |||||
Charging current | 10A,20A,30A,40A,50A,60A | ||||||
PV Input Voltage Range | 12V System:15V-44V;24V System:30V-44V;48V System:60V-88V | ||||||
Max PV Input Voltage (At 25℃) | 12V/24V System:50V;48V System:100V | ||||||
PV Array Maximum Power | 12V System:140W,280W,420W,560W,700W,840W; 24V System:280W,360W,840W,1120W,1400W,1680W; 48V System:560W,1120W,1680W,1120W,2240W,3360W | ||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||
AC Charging current(selectable) | 0~30A | ||||||
Transfer Time | ≤4ms | ||||||
Display | LCD | ||||||
Thermal method | Cooling fan in intelligent control | ||||||
Battery Type (selectable|) | LEAD | Charge Voltage:14V;Float Voltage:13.8V(Single battery voltage,x2 for 24V; x4 for 48V) | |||||
OP-LE | Charge Voltage:14.2V;Float Voltage:13.8V(Single battery voltage,x2 for 24V; x4 for 48V) | ||||||
LITHIUM | Charge Voltage:13V;Float Voltage:12.6V(Single battery voltage,x2 for 24V; x4 for 48V) | ||||||
Remark | The charging parameters of other types battery can be user-defined | ||||||
Protection | Over-load / Over-discharge / Short circuit / High temperayure / Reverse polarity | ||||||
Communication | RS232/RS485(Optional) | ||||||
Environment | Noise | ≤55dB | |||||
Temperature | -10℃~40℃ | ||||||
Humidity | 0~95%( No condensation) | ||||||
Note : All specifications are subject to charge without prior notice |
To be added……
Product certification:
CE、IEC
Application area
◆ Domestic appliance:fan,lamp,rice cooker, etc.
◇ Office equipment:computers, printers, etc.
◆ Electronic communications: DVD, monitoring devices, communication stations, etc.
◇ Electric tools: electric drill, punching machine, water pump, etc.
◆ Vehicle and ship equipment: ambulances, ships, traffic lights, etc.
◇ Emergency power supply: standby power supply
◆ Pure sine wave output;
◇ Built-in PWM charge controller optional;
◆ AC charge current 0-30A adjustable; AVR output;
◇ Low frequency toroidal transformer increase efficiency;
◆ Dedicated DCP chip design; stable and high-speed operation;
◇ Added fault code query function, easy to monitor the operation in real time;
◆ Supports diesel or gasoline generator, adapt any tough electricity situation;
◇ RS232 or RS485 communication port optional.
To be added……
◆ Pure sine wave output;
◇ Built-in PWM charge controller optional;
◆ AC charge current 0-30A adjustable; AVR output;
◇ Low frequency toroidal transformer increase efficiency;
◆ Dedicated DCP chip design; stable and high-speed operation;
◇ Added fault code query function, easy to monitor the operation in real time;
◆ Supports diesel or gasoline generator, adapt any tough electricity situation;
◇ RS232 or RS485 communication port optional.
To be added……
¥0
库存充足
已选0
购买 数量