pecifications: | |||||||
| Model XD- | T10224-20 | ||||||
| PV Controller | Control mode | Direct charge/PWM | |||||
| Charge current | 20A | ||||||
| Rated charging voltage | 24VDC | ||||||
| Compulsive charging voltage | 29.6V | ||||||
| Balanced charging voltage | 28.8V | ||||||
| Floating charging voltage | 27.6V | ||||||
| Recovery charging voltage | 26.6 | ||||||
| Battery overvoltage protection/recovery | 33V/30V | ||||||
| Protection function | Reverse connection, short circuit, overcharge, anti charge protection | ||||||
| Display | LED | ||||||
| PV Inverter | Rated Capacity | 1000W | |||||
| DC voltage | 24V | ||||||
| Undervoltage protection | 10.5V | ||||||
| Inverter structure | Power frequency structure | ||||||
| Mains input | 100V/110V/120V/127V/220V/230V/240V(±25%) | ||||||
| Inverter output | 100V/110V/120V/127V/220V/230V/240V(±2%) | ||||||
| Mains input charging current | 10A | ||||||
| Working way | Mains priority/solar power priority (optional) | ||||||
| Conversion time | ≤4ms | ||||||
| Overload capacity | Overload 110% 30 seconds the machine automatically shut down; overload shutdown 120% 2 seconds; mains mode overload do not shutdown | ||||||
| Conversion efficiency | ≥80% | ||||||
| Output waveform | Pure sine wave | ||||||
| Work environment | Temperature0-40°C,Humidity10-90% | ||||||
| Cooling mode | Forced air cooling | ||||||
| Protection function | Mains over / under-voltage, direct current is too high / undervoltage, the inverter output short circuit | ||||||
| Display | LCD | ||||||
| Output waveform distortion | ≤±0.3% | ||||||
| Input and output frequency | The same with power system | ||||||
| Machine specifications | Size(mm) | 420*145*215 | |||||
| Total G.W(KG) | 13KG | ||||||
| Remarks | Specification for reference.Subject to change without prior notice | ||||||